Technical data
General technical data
Applied standards
EN 60947-5-1, EN ISO 14119, EN IEC 60079-0, EN 60079-1, EN IEC 60079-7, EN 60079-18, EN 60079-31, EN ISO 13849-1
Enclosure
thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
Actuator
stainless steel 1.4301
Switch type
type 2
Coding level
low coding
Tightening torque
cover screws: 0.5 … 0.6 Nm
enclosure mounting screws: 1 … 1.3 Nm
switch inserts M3 screw connection terminals: min. 0.6 Nm
solenoid M3.5 screw connection terminals: min. 0.8 Nm
Degree of protection
IP64 (IEC/EN 60529)
B10d (10 % load)
1 million
TM
max. 20 years
Contact material
silver
Switching system
slow action, positive break NC contacts A
Switching elements
1 NC/1 NO contact + 1 NC/1 NO contact or 2 NC + 1 NC/1 NO contact or 2 NC/1 NO contact + 2 NC/1 NO contact, type Zb
Connection
screw connection terminals
Cable cross-section
solenoid: 0.2 … 1.5 mm2 (AWG 24 … 16)
switch inserts: 0.75 … 1.5 mm2 (AWG 18 … 16)
Cable entry
2 x M20 x 1.5 (incl. 1 cable gland)
Clamping range
7 … 12 mm
Rated insulation voltage Ui
250 V
Rated impulse withstand voltage Uimp
4 kV
Utilisation category
AC-15; DC-13
Rated operating current/voltage Ie/Ue
enabling/signalling contacts: 3 A/250 VAC; 0.25 A/230 VDC or 1.5 A/250 VAC; 0,25 A/230 VDC;
direct-current solenoid: 0.08 A / 24 VDC +10 %/–15 %
Short-circuit protection
3 A / 1.5 A gG/gN fuse;
direct-current solenoid: 2 A (slow blow)
Power consumption
<2.5 W (continuous operation), max. 47 W (for 250 ms)
Operation cycles
max. 1200/h
Mechanical life
> 500 000 operations
Locking force Fmax
1000 N
Impact energy
max. 7 J
Ambient temperature
–20 °C … +55 °C
Ex marking
L II 2G Ex db eb mb IIC T4 Gb,
L II 2D Ex tb IIIC T100 °C Db
IECEx Ex db eb mb IIC T4 Gb,
Ex tb IIIC T100 °C Db
Approvals
BVS 10 ATEX E 053 X
IECEx BVS 11.0030X
f *
d *
Ü *
a *
* depending on the variant
Downloads
Variants / Options
The following variants / options are available on request:
Actuator turned by 90°