Technical data

Applied standards

EN 60947-5-1, EN IEC 60079-0, EN 60079-1, EN IEC 60079-7, EN 60079-31, EN ISO 13849-1, EN ISO 14119

Enclosure

zinc die-cast, enamel finish

Actuator

stainless steel 1.4301

Switch type

type 2

Coding level

low coding

Degree of protection

IP67 (IEC/EN 60529)

B10d (10 % load)

2 million

TM

max. 20 years

Switch insert

1 x Ex 95

Contact material

silver

Switching system

slow action, positive break NC contacts A

Switching elements

1 NC/1 NO contact or 2 NC contacts, type Zb

Connection

screw connection terminals

Cable cross-section

max. 1.5 mm² (incl. conductor ferrules)

Cable entry

3 x M20 x 1.5 (incl. 1 cable gland)

Clamping range

7 … 12 mm

Rated impulse withstand voltage Uimp

4 kV

Rated insulation voltage Ui

250 V

Conventional thermal current Ithe

6 A

Rated operating current/voltage Ie/Ue

6 A/250 VAC; 0.25 A/230 VDC

Utilisation category

AC-15; DC-13

Short-circuit protection

6 A gG/gN fuse

Positive break travel

8.3 mm

Ambient temperature

T6: –20 °C … +40 °C;
T5: –20 °C … +60 °C

Mechanical life

> 1 million operations

Impact energy

max. 7 J

Ex marking

L II 2G Ex db e IIC T6/T5 Gb,
L II 2D Ex tb IIIC T80 °C/T95 °C Db
IECEx Ex db e IIC T6/T5 Gb,
Ex tb IIIC T80 °C/T95 °C Db

Approvals

BVS 04 ATEX E 126
IECEx BVS 07.0013

Downloads

Loading...
Mounting and wiring instructions – Ex 355

German, English, French, Italian, Portuguese, Russian

PDF 2 MB 03.07.2024
Please go to the relevant product pages for additional downloads.

Variants / Options

The following variants / options are available on request:

  • Actuator head can be repositioned in factory by 4 x 90°

  • Special version only for dust Ex zone 22

to your contact persons