Product features
Thermoplastic enclosure
Double insulated X
Mounting details to EN 50047
With pre-wired cable
Actuator: Ball plunger for front mounting FKU
Actuating speed max. 0.5 m/s with a vertical actuating angle of 20°
Vertical actuation or actuation from side possible
Actuator with captive stainless steel ball
Exact repeatability of switching point
Technical data
General technical data
Applied standards
EN 60947-5-1
Enclosure
thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
Degree of protection
IP67 (IEC/EN 60529)
Contact material
silver
Switching system
snap action
Switching elements
1 change-over contact with single break, type C
Connection
pre-wired cable H05VV-F
Cable cross-section
3 x 0.75 mm²
Cable length
5 m
Rated impulse withstand voltage Uimp
4 kV
Rated insulation voltage Ui
250 V
Conventional thermal current Ithe
5 A
Rated operating current/voltage Ie/Ue
5 A/250 VAC; 0.16 A/230 VDC
Utilisation category
AC-15; DC-13
Short-circuit protection
5 A gG/gN fuse
Ambient temperature
–20 °C … +75 °C
Mechanical life
> 1 million operations
Operation cycles
max. 1800/h
Repeat accuracy of switching points
± 0.1 mm
Contact opening
max. 2 x 4 mm
Approvals
]
Downloads
Variants / Options
The following variants / options are available on request:
Cable entry on side
Plug-in connector M12 x 1, 4-pole
Gold-plated contacts
Latching element (On-/Off principle)
Version with UL/CSA approval
Contact overlapping (only slow action)