Ex safety foot switch

Ex GFS VD


  • Ex zone 1 and 21

  • 1-pedal type

  • Metal enclosure

  • With protective shield

  • Low pedal height

  • With pre-wired cable

Technical data

Applied standards

EN 60947-5-1, EN IEC 60079-0, EN 60079-1, EN 60079-31, EN ISO 13849-1

Enclosure

aluminium die-cast, powder-coated

Pedal

thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0

Protective shield

aluminium die-cast, powder-coated

Degree of protection

IP65 (IEC/EN 60529)

B10d (10 % load)

2 million

TM

max. 20 years

Connection

2 x pre-wired cable H03VV-F

Cable cross-section

2 x 0.75 mm²

Cable length

5 m

Contact material

silver

Switch insert

1 x Ex 14 1S + 1 x Ex 14 1Ö VD

Utilisation category

AC-15; DC-13

Rated operating current/voltage Ie/Ue

6 A/250 VAC; 0.25 A/230 VDC

Short-circuit protection

6 A gG/gN fuse

Ambient temperature

T6: –20 °C … +60 °C,
T5: –20 °C … +75 °C

Mechanical life

> 1 million operations

Ex marking

L II 2G Ex d IIC T6/T5 Gb,
L II 2D Ex tb IIIC T80 °C/T95 °C Db IP65
IECEx Ex d IIC T6/T5 Gb,
Ex tb IIIC T80 °C/T95 °C Db IP65

Approvals

PTB 11 ATEX 1002 X
IECEx PTB 11.0090X

Downloads

Loading...
Mounting and wiring instructions – Ex GF / Ex GFS

German, English, French, Italian, Portuguese

PDF 2 MB 28.09.2023