Foot switch with metal enclosure

GFSI Extreme


  • Corrosion-resistant aluminium enclosure

  • Salt-mist spray test to DIN EN ISO 9227

  • High degree of protection IP66, IP67, IP69, IP69K depending on selected cable gland

  • Temperature resistant from -40 °C to +90 °C

  • Screws and metal parts made of stainless steel

  • Suitable for the food processing industry

  • With protective shield

  • Max. 4 contacts

  • Attention: Please state required international approvals with your order!

Technical data

Applied standards

EN 60947-5-1

Enclosure

aluminium die-cast, corrosion-resistant, powder-coated, passivated, anthracite grey, similar to RAL 7016

Pedal

aluminium die-cast, corrosion-resistant, hard-coated, powder-coated, anthracite grey, similar to RAL 7016

Protective shield

aluminium die-cast, corrosion-resistant, powder-coated, passivated, signal yellow, similar to RAL 1003

Degree of protection

IP66, IP67, IP69 (IEC/EN 60529) / IP69K (ISO 20653) depending on selected cable gland

B10d (10 % load)

2 million

TM

max. 20 years

Connection

screw connection terminals

Cable cross-section

max. 2.5 mm² (incl. conductor ferrules)

Cable entry

1 x M20 x 1.5

Contact material

silver

Switching system

slow action, positive break NC contacts A

Switching elements

1 NC/1 NO contact or 2 NC/2 NO contacts, type Zb

Utilisation category

AC-15

Ambient temperature

–40 °C … +90 °C

Mechanical life

> 1 million operations

Approvals

d ]

Downloads

Loading...
Mounting and wiring instructions – GFI / GFSI Extreme

German, English, French, Italian, Portuguese, Russian

PDF 5 MB 28.09.2023
Please go to the relevant product pages for additional downloads.