Ex emergency pull-wire switch

Ex ZS 92 S-3D


  • Ex zone 22

  • Corrosion-resistant aluminium enclosure

  • Screws made of stainless steel

  • Wire length up to 2 x 100 m

  • Release by lever

  • F = Reset lever at the front side

  • Back and base mounting possible

  • Wire pull and breakage detection

Technical data

Applied standards

EN 60947-5-1, EN 60947-5-5, EN ISO 13850, EN ISO 13849-1, EN IEC 60079-0, EN 60079-31, EN 620-5.7.2.9, AS 1755-2000-2.7.9.1, AS/NZS 4024.3610:2015-2.10.6.2

Enclosure

aluminium die-cast, corrosion-resistant, powder-coated, passivated, shockproof, anthracite grey, similar to RAL 7016

Cover

aluminium die-cast, corrosion-resistant, powder-coated, passivated, shockproof, signal yellow, similar to RAL 1003

Actuating lever

aluminium die-cast, corrosion-resistant, powder-coated, passivated, shockproof, signal red, similar to RAL 3001

Reset lever

aluminium die-cast, corrosion-resistant, powder-coated, passivated, shockproof, sky blue, similar to RAL 5015

Screws

stainless steel

Tightening torque

cover screws: max. 2.5 Nm
actuator screws: max. 6 Nm

Degree of protection

IP66 (EN 60079-0 + IEC/EN 60529)

B10d (10 % load)

100 000

TM

max. 20 years

Contact material

silver

Switching system

snap action, positive break NC contacts A

Switching elements

2 NC/2 NO contacts, type Zb

Connection

screw connection terminals

Cable cross-section

min. 0.75 mm² (AWG 18), max. 2.5 mm² (AWG 14), incl. conductor ferrules

Cable entry

2 x M25 x 1.5

Rated impulse withstand voltage Uimp

6 kV

Rated insulation voltage Ui

250 V

Conventional thermal current Ithe

2 A / 4 A / 6 A

Utilisation category

AC-15

Rated operating current/voltage Ie/Ue

max. 2 A/4 A/6 A / 250 VAC

Short-circuit protection

2 A / 4 A / 6 A gG/gN fuse

Mechanical life

> 50 000 operations

Max. wire length

2 x 100 m

Ambient temperature

–20 °C … +55 °C max. 2 A,
–20 °C … +50 °C max. 4 A,
–20 °C … +45 °C max. 6 A

Degree of pollution

3

Actuating force

actuating lever approx. 30 N; reset lever approx. 40 N

Ex marking

L II 3D Ex tc IIIC T80°C Dc

Downloads

Loading...
Mounting and wiring instructions – Ex ZS 92 S-3D

German, English, French, Italian, Portuguese, Russian

PDF 6 MB 04.10.2023
Please go to the relevant product pages for additional downloads.
Loading...

Other interesting products

2G/D version for Ex zone 1 and 21

Ex Safety