Ex safety sensor

Ex HS Si 4 - 3G/D


  • Ex zone 2 and 22

  • Thermoplastic enclosure

  • Hall elements, coded

  • Actuation from front

  • Switching distance up to 7 mm

  • With pre-wired cable

Notes
  • The actuator is not included in the delivery of the switches

Technical data

Applied standards

EN IEC 60079-0, EN 60079-18, EN 60947-5-2, EN 60947-5-3, EN ISO 14119, EN ISO 13849-1, EN 62061

Enclosure

thermoplastic, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0

Defined object

actuator Ex MC 4

Sensor type

type 4 interlocking device

Coding level

low coding

Degree of protection

IP67 (IEC/EN 60529)

Switching system

Hall sensor, 2 galvanically separated channels, semiconductor

Connection

cable 6 x AWG 26

Rated operating voltage Ue

24 VDC

Rated operating voltage range UB

10 … 30 VDC

Rated operating current Ie

max. 40 mA per channel

Utilisation category

DC-12

No-load supply current I0

max. 6 mA per channel

Voltage drop at Ie

max. 2.5 V

Switch-on/switch-off time

< 1 ms

Short-circuit protection

< 50 mA internal reversible fuse

Switching frequency

max. 100 Hz

Safety class

II

Degree of pollution

3

Ambient temperature

–20 °C … +60 °C

Mechanical life

> 10 million operations

Rated switching distance sn 

7 mm

Assured switching distance »ON« sao

6 mm

Assured switching distance »OFF« sar 

20 mm

Repeatability

≤ 5 %

Impact energy

max. 7 J

Ex marking

L II 3G Ex mc IIC T6 Gc X,
L II 3D Ex mc IIIC T80°C Dc

Switching elements

1 NC/1 NO contact or 2 NC contacts

EN ISO 13849-1

Performance Level PL e

Category

4

TM

max. 20 years

MTTFd

> 100 years

DC/DCavg

> 99 %

EN 62061

SIL CL 3

PFHd

≥ 2.47 x 10-8 1/h

Note

The safety-related data are only valid in combination with a safety module, e.g. SRM 21 RT2 (mat. no. 1179203).
 