Product features
Thermoplastic enclosure
Design to EN 50047
sWave® wireless technology
No power supply, no wiring and pipe laying required
Easy programming of receiver
Output signal can be individually configured at the receiver
Actuator: Rod lever DD
Lever angle adjustable in 10° steps
Actuator can be repositioned by 4 x 90°
Technical data
General technical data
Applied standards
EN 60947-5-1, EN 61000-6-2, EN 61000-6-3, EN 61000-4-2, EN 301 489-1, EN 301 489-3, EN 300 220-1, EN 300 220-2
Enclosure
thermoplastic, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0
Cover
thermoplastic, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0
Tightening torque
enclosure mounting screws: 1.2 … 1.3 Nm
cover screws: 0.5 … 0.6 Nm
Degree of protection
IP67 (IEC/EN 60529)
Voltage source
electrodynamic energy generator
Ambient temperature
–20 °C … +65 °C
Operation cycles
max. 12000 telegrams with repetitions/h
Mechanical life
> 1 million operations
Actuating time
min. 80 ms
Note
no status signal available
Wireless approvals
Brazil: ANATEL 04580-18-06718
Wireless technology
Protocol
sWave®
Frequency
917 MHz (Brazil)
Transmission power
< 25 mW
Data rate
66 kbps
Channel bandwidth
550 kHz
Wireless range
max. 700 m outdoors, max. 50 m indoors