Product features
Ex zone 21
Temperature resistant from -30 °C to +65 °C
Corrosion-resistant aluminium enclosure
Screws and belt-alignment roller made of stainless steel
With staggered contacts, adjustable from 5° to 35°
Belt alignment lever adjustable in 12° steps using a self-locking mechanism
Rear and base mounting possible
Enclosure with ventilation plug
Technical data
General technical data
Applied standards
EN 60947-5-1, EN IEC 60079-0, EN 60079-31
Enclosure
aluminium die-cast, corrosion-resistant, powder-coated, passivated, shockproof, anthracite grey, similar to RAL 7016
Cover
aluminium die-cast, corrosion-resistant, powder-coated, passivated, shockproof, signal yellow, similar to RAL 1003
Tightening torque
cover screws: max. 2.5 Nm
Degree of protection
IP66 (EN 60079-0 + IEC/EN 60529)
B10d (10 % load)
2 million
TM
max. 20 years
Contact material
silver
Switching elements
2 NC/2 NO contacts, type Zb
Switching system
snap action, positive break NC contacts A
Switching points
adjustable 5° to 35°; pre-adjustment setting 2 x 10°
Connection
screw connection terminals
Cable cross-section
0.5 ... 2.5 mm² (incl. conductor ferrules)
Cable entry
2 x M25 x 1.5
Rated impulse withstand voltage Uimp
6 kV
Rated insulation voltage Ui
250 V
Conventional thermal current Ithe
2 A / 4 A / 6 A
Conditional short-circuit current
1100 A
Utilisation category
AC-15
Rated operating current/voltage Ie/Ue
max. 2 A/4 A/6 A / 250 VAC
Short-circuit protection
2 A / 4 A / 6 A gG/gN fuse
Mechanical life
> 1 000 000 operations at max. 45° operating angle
Admissible belt speed
7 m/s for 3 h with a force of 50 N
Operation cycles
max. 600/h
Ambient temperature
–30 °C … +65 °C max. 2 A,
–30 °C … +60 °C max. 4 A,
–30 °C … +55 °C max. 6 A
Degree of pollution
3
Ex marking
L II 2D Ex tb IIIC T80°C Db
IECEx Ex tb IIIC T80 °C Db
Approvals
BVS 19 ATEX E 076
IECEx BVS 19.0074
f d a