new

Ex solenoid interlock

Ex STM 515 11/11 R TB/FE L-3G/D

Article no.: 1304434

contact us

Product features

ExSafety
  • Ex zone 2 and 22

  • High degree of protection IP66 / IP67

  • Corrosion-resistant aluminium enclosure

  • Wiring compartment

  • Spring-to-lock principle

  • Actuator head can be repositioned by 4 x 90°

  • TB: Escape release back side (release by turning with a handwheel)

  • FE: Auxiliary release front side (release by turning with a triangular key M5)

Technical data

Applied standards

EN 60947-5-1, EN IEC 60079-0, EN 60079-1, EN IEC 60079-7, EN 60079-18, EN 60079-31, EN ISO 14119, EN ISO 13849-1

Enclosure

aluminium die-cast, corrosion-resistant, impact resistant, powder-coated, passivated, anthracite grey, similar to RAL 7016

Cover

aluminium die-cast, corrosion-resistant, impact resistant, powder-coated, passivated, signal yellow, similar to RAL 1003

Actuator head

thermoset, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0

Screws

stainless steel

Switch type

type 2

Coding level

low coding

Tightening torque

cover screws: max. 2.5 Nm
actuator head: max. 2.5 Nm
enclosure mounting screws: 8 Nm
switch inserts M3 screw connection terminals: min. 0.6 Nm
solenoid M3.5 screw connection terminals: min. 0.8 Nm

Degree of protection

IP66/IP67 (IEC/EN 60529)

B10d (10 % load)

2 million

TM

max. 20 years

Mounting

4 x M6 cylinder head screw (e.g. DIN 912 / ISO 4762)

Mounting position

any

Safety class

I

Switching system

slow action, positive break NC contacts A

Switching elements

1 NC/1 NO contact + 1 NC/1 NO contact, type Zb

Contact material

silver

Connection

screw connection terminals

Cable cross-section

solenoid: 0.5 … 1.5 mm2 (AWG 20 … 16)
switch inserts: 0.75 … 1.5 mm2 (AWG 18 … 16)

Clamping range

7 … 12 mm

Cable entry

2 x M20 x 1.5

Rated insulation voltage Ui

250 V

Rated impulse withstand voltage Uimp

4 kV

Conventional thermal current Ithe

6 A

Conditional short-circuit current

1000 A

Utilisation category

AC-15; DC-13

Rated operating current/voltage Ie/Ue

enabling/signalling contacts: 6 A/250 VAC; 0.25 A/230 VDC;
direct-current solenoid: 0.08 A / 24 VDC +10 %/–15 %

Short-circuit protection

6 A gG/gN fuse;
direct-current solenoid: 2 A (slow blow)

Power consumption

<2.5 W (continuous operation), max. 47 W (for 250 ms)

Locking force Fmax

5500 N

Locking force FZh

4000 N

Actuating speed V

≤ 0.3 m/s

Actuating force / Latching force

≥ 40 N (retraction and extension of actuator)

Operation cycles

max. 900/h

Mechanical life

1 million operations

Impact energy

max. 7 J

Ambient temperature

–20 °C … +55 °C

Degree of pollution

3

Ex marking

L II 3G Ex dc ec mc IIC T4 Gc X
L II 3D Ex tc IIIC T100°C Dc X

Downloads

Loading...
Mounting and wiring instructions – Ex STM 515-3G/D

German, English, French, Italian, Portuguese

PDF4 MB 16.02.2024
Loading...

Other interesting products

2G/D version for Ex zone 1 and 21

ExSafety
new

Ex solenoid interlock

Ex STM 515 11/11 R TB/FE L-3G/D

Article no.: 1304434

contact us