Product features
Thermoplastic enclosure
Double insulated X
Mounting details to EN 50047
Suitable for in-line mounting
With pre-wired cable
Actuator: Ball plunger with collar WKU
Actuating speed max. 0.5 m/s with a vertical actuating angle of 20°
Vertical actuation or actuation from side possible
Actuator with captive stainless steel ball
Exact repeatability of switching point
Watertight collar for protection against penetration of dirt
Technical data
General technical data
Applied standards
EN 60947-5-1
Enclosure
thermoplastic, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0
Degree of protection
IP67 (IEC/EN 60529)
Contact material
silver
Switching system
snap action
Switching elements
1 NC/1 NO contact, type Za
Connection
pre-wired cable H05VV-F
Cable cross-section
4 x 0.75 mm²
Cable length
5 m
Rated impulse withstand voltage Uimp
4 kV
Rated insulation voltage Ui
250 V
Conventional thermal current Ithe
5 A
Rated operating current/voltage Ie/Ue
5 A/250 VAC; 0.16 A/230 VDC
Utilisation category
AC-15; DC-13
Short-circuit protection
5 A gG/gN fuse
Ambient temperature
–20 °C … +75 °C
Mechanical life
> 1 million operations
Operation cycles
max. 1800/h
Repeat accuracy of switching points
± 0.1 mm
Contact opening
max. 2 x 4 mm
Approvals
a
Downloads
Variants / Options
The following variants / options are available on request:
Cable entry on side
Connector M12 x 1, 4-pole
Gold-plated contacts
Latching element (On-/Off principle)
Version with UL/CSA approval
Contact overlapping (only slow action)