Product features
Thermoplastic enclosure
Double insulated X
Mounting details to EN 50047
Suitable for in-line mounting
With pre-wired cable
Actuator: Long spring rod TL
Spring rod can be actuated from any direction
Spring rod can be shortened 30 mm in actuating area
Exact linear actuation not necessary
Elasticity of the spring allows for deflection above the max. switching angle of 18°
Technical data
General technical data
Applied standards
EN 60947-5-1
Enclosure
thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
Degree of protection
IP67 (IEC/EN 60529)
Contact material
silver
Switching system
slow action
Switching elements
2 NC/1 NO contact, type Zb
Connection
cable 6 x AWG 20
Cable cross-section
6 x 0.56 mm²
Cable length
2 m
Rated impulse withstand voltage Uimp
4 kV
Rated insulation voltage Ui
250 V
Conventional thermal current Ithe
6 A
Rated operating current/voltage Ie/Ue
6 A/250 VAC; 0.25 A/230 VDC
Utilisation category
AC-15; DC-13
Short-circuit protection
6 A gG/gN fuse
Ambient temperature
–20 °C … +75 °C
Mechanical life
> 1 million operations
Operation cycles
max. 1800/h
Repeat accuracy of switching points
± 0.1 mm
Contact opening
max. 2 x 4 mm
Approvals
]
Downloads
Variants / Options
The following variants / options are available on request:
- Cable entry on side
- Plug-in connector M12 x 1, 4-pole
- Gold-plated contacts
- Latching element (On-/Off principle)
- Version with UL/CSA approval
- Contact overlapping (only slow action)